Turbine Observations
• There is minimal surface indication of a turbine stalling.
• Turbines do not readily allow the pumping of LCM.
• Sand content of the drilling fluid should be kept to a minimum.
• Due to minimal rubber components, the turbine is able to operate in
high temperature wells.
• Pressure drop through the tool is typically high and can be anything
from 500 psi to over 2000 psi.
• Turbines do not require a by-pass valve.
• Usually, the maximum allowable bearing wear is of the order of 4mm.